91枚の写真
所在地
Mondovi, WI
Mondovi, WI
使用状況
2,786 時間
2,786 時間
シリアル番号
AGCA1100KKNNL1161
AGCA1100KKNNL1161
Loading...
このロットは、IronClad保険によって保護されています
このロットは有資格検査員による十分かつ詳細な検査を受けています。安心してご購入ください。
ID番号
#15048397
ヤード内
いいえ
機能
2786 Machine Hours Showing, Hydrostatic, Air Conditioner, Raven Display, Raven Antenna/ Receiver, Requires Diesel Exhaust Fluid, Hydraulic Driven Pump, 1100 gal Stainless Steel Tank, Foam Markers, Rinse Tank, 380/90R46, 380/90R46 Rear Tires

























Serial Number / VIN
AGCA1100KKNNL1161
Hour Meter / Odometer
2786 hrs-No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed.
Paint
Sheet Metal (fiberglass) Condition
Steps/Ladders
Hand Rails
Glass
Exterior Lights
Operational
Travel Alarm
Operational
Horn
Operational
Seat Belts
Operational
Current Safety Manual
Current Operator/Maintenance Manual








Mirrors
Seats/Armrests
Passenger seat
Yes
Hydraulic Controls
Steering Control
Drivetrain Controls
Oil Pressure
The fault indicator shuts off after the engine oil pressure rises.
Warning Lights
Operational
Gauges
Operational
Air Conditioner
The ambient temperature is too cold to check
Heater
Operational
Limited Function Check
The main components are in place and operational as noted.








Engine
Requires Diesel Exhaust Fluid
A/C Compressor
In place; ambient temperature too cold to check operation
Blow-by (subjective visual observation)
No noticeable vapor or pressure
Starter
Operational
Exhaust System
Radiator
Oil Leaks
No dripping leaks
Engine - Left Side
Engine - Right Side
DEF / AdBlue Tank
Limited Function Check
The engine started and ran.









Transmission
Drive/Propel Motors
Front Drive Axle
Rear Drive Axle
Limited Function Check
The drivetrain was operational.










Pumps (Hydraulics)
Valves
Hydraulic Tank
Hoses
Cylinder(s)
Cylinder Pins and Bushings
Limited Function Check
The hydraulic system was operational.































Booms and Boom Tree
Boom Shocks
Tank
Tank Saddle
Plumbing
Electrical
Foam Marker
Fluid Flush System
Pressure Gauge System
Controller
Appears complete, Make and Model Raven
Steering Linkage
Brake Type
Hydrostatic, Air
Brake Control
Brake Lines/Hoses
Not operationally checked
Park Brake
Stopped from a slow roll
Limited Function Check - Brakes
The brake system functioned, stopping and holding the machine.
Frame Condition
Left Front Tire
Left Rear Tire
Right Rear Tire
Right Front Tire
Tread Depth
LF 27 /32", LR 25 /32", RR 13 /32", RF 13 /32"
Wheel Condition
Wheel Studs, Nuts, Lugs
Oil Sample Analysis
| engine | |
|---|---|
| date of analysis | Apr 21, 2026 |
| Silicon | 0.25 PPM |
| Tin | 1.09 PPM |
| Silver | 0.05 PPM |
| Aluminum | 0.88 PPM |
| Chromium | 0.26 PPM |
| Lead | 8.35 PPM |
| Copper | 2.91 PPM |
| Nickel | 0.34 PPM |
| Iron | 14.63 PPM |
| Glycol | NEG |
| Water | NEG |
| Fuel | <5% |
Ritchie Bros.の充実したドアツードア物流および配送ソリューションで、機器を必要な場所にお届けします。国境、大陸、海を越えてお客様の機器を迅速かつ効率的にお届けするオールインクルーシブサービスで、輸送のすべての工程に対応いたします
機械の詳細情報は範囲に制限があり、Ritchie Bros. Auctioneersは、ここに明記するもの以外の設備やコンポーメントの検査は行っていません。特に明記されていない限り、明示的または黙示的かにかかわらず、Ritchie Bros.は機械やそのコンポーネントに関する一切の責任を負わないものとします。機能性、快適性、あるいは関係官庁や規制機関が定める安全基準や要件に関する準拠性、特定目的への適合性、または商品性に関する表明や保証も含まれますが、これらに限るわけではありません。お客様には入札される前に必ず機械の検品を行うことをお勧めします。
機械は負荷の下でのテスト、または利用可能なすべてのギアを使用してのテストを行ったわけではありません。機械が、メーカーの仕様に従って動作されていたか保証はできません。ここで公開されている以外の機能性テストは実施されていません。個々のアンダーキャリッジコンポーネントについては選択中の写真のみが提供されています。このため、アンダーキャリッジ全体の状態を示さないことがあります。
寸法は、あくまで参考として表示されています。実際に積載された状態での寸法は、トラックやトレーラーの高さ、積載された機械の構成や位置により異なります。オークションの会場から搬出する前に、すべての積載物が運搬可能な状態になっているかの確認は、バイヤーの責任になります。全寸法は、お客様によって採寸・確認を行うようお願いします。運搬に際して、これらの寸法はあくまで参考としてお使いください。