124枚の写真
2012 Elgin Broom Bear on 2012 Freightliner M2 106 道路清掃車
Middlefield, OH
所在地
Middlefield, OH
Middlefield, OH
使用状況
84,500 mi
84,500 mi
シリアル番号
1FVACXBS4CHBW0849
1FVACXBS4CHBW0849
近日公開
この取引はIronPlanetにより提供され、IronPlanetを通じて行われます。
配送が簡単になりました
機械の詳細情報
ID番号
#15544378
ヤード内
いいえ
機能
Cummins 6 Cylinder 8.3 L Diesel Engine, Requires Diesel Exhaust Fluid, 10231.9 Engine hrs, Air Conditioner, Cruise Control, Allison Automatic Transmission, Air Ride Cab, 295/75R22.5 Front Tires, 11R22.5 Rear Tires, Airliner Air Ride Suspension, 136 in Wheelbase, PTO, Mechanical Broom Sweeper, Dual Controls, Front Spray Bar, 58 in Rear Broom, Gutter Brooms, Material Elevator, Water System, Hydraulic Dump, Rear View Camera
注記
**Title may not be available for up to 25 business days after auction.**
General Appearance
(25)
























Serial Number / VIN
1FVACXBS4CHBW0849, The serial number is not legible. This unit may be difficult to export.
Frame Stamp Serial Number/VIN Photo
Hour Meter / Odometer
84500 mi-No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed.
Motor Vehicle Safety Standards Label
No
Paint
Sheet Metal (fiberglass) Condition
Steps/Ladders
Hand Rails
Glass
Windshield has cracks
Exterior Lights
Operational
Brakes / Tires
Steer Axle
- 16/32" Steel
- Covered
- Covered
- 16/32" Steel
Rear Axle
- 6/32" Steel
- 8/32" Steel
- Drum
- Drum
- 9/32" Steel
- 9/32" Steel
Engine
(12)











Emissions Information
No US EPA Label Present Requires Diesel Exhaust Fluid
A/C Compressor
Operational
Blow-by (subjective visual observation)
No noticeable vapor or pressure
Starter
Operational
Air Compressor
Operational
Fuel System
Operational
Exhaust System
Diesel Particulate Filter
Radiator
Oil Leaks
No dripping leaks
Fuel Leaks
No dripping leaks
Cooling System Leaks
No dripping leaks
Engine - Left Side
Engine - Right Side
DEF / AdBlue Tank
Limited Function Check
The engine started and ran.
Cab
(5)




Engine Hours
10231.9 Engine hrs
Control Station
(22)





















Mirrors
Window Controls
Both Manual
Seats/armrests
Seat Belts
Operational
Horn
Electric horn operational
Oil Pressure
The gauge registers in the operating range. 68 PSI
Warning Lights
Operational, ABS light stays on
Travel Alarm
Inoperable
Gauges
Left side operational, Right side operational
Max. Air Pressure Reading
120 psi
Odometer Reading
Left side: 83625.9 miles-IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.Odometer Reading
Air Conditioner
Operational
Heater
Operational
Limited Function Check
The main components are in place and operational as noted.
Drivetrain
(3)


Transmission
Operational
Transmission Leaks
None Seen
Drive Shaft
Power Take Off
Operational
Rear Drive Axle
Limited Function Check
The drivetrain was operational.
Hydraulics
(21)




















Pumps (Hydraulics)
Hydraulic Motors
Valves
Hydraulic Tank
Hoses
Cylinder(s)
Cylinder Pins and Bushings
Limited Function Check
The hydraulic system was operational.
Chassis
(32)































Steering Linkage
Brake Type
Air brakes
Master Cylinder/Brake Control
Brake Lines/Hoses
Park Brake
Held against power
Limited Function Check - Brakes
The brake system functioned, stopping and holding the machine.
Springs/Hangers Condition
Suspension Air Bags
Suspension Bushings
Frame Condition
Left Steer Tire
Left Rear Drive Tires
Right Rear Drive Tires
Right Steer Tire
Wheel Condition
Lugs
Debris Tank
Main Broom
Gutter Brooms
Water Tank
Not operationally checked
Pressure Pump - Water
Elevator Chains/Belts
Elevator Sprockets
Elevator Flights
Heavy wear
Limited Function Check
The main components were operational when checked without a load.
Configuration
(4)



Oil Sample Analysis
Oil Sample Analysis
| engine | transmission | |
|---|---|---|
| date of analysis | Jul 22, 2026 | Jul 22, 2026 |
| Silicon | 0.13 PPM | 2.8 PPM |
| Tin | 1.38 PPM | 3.21 PPM |
| Silver | 0.02 PPM | 0.01 PPM |
| Aluminum | 4.34 PPM | 17.41 PPM |
| Chromium | 1.05 PPM | 0 PPM |
| Lead | 2.93 PPM | 6.07 PPM |
| Copper | 1.79 PPM | 37.79 PPM |
| Nickel | 0.98 PPM | 0.26 PPM |
| Iron | 97.87 PPM | 105.71 PPM |
| Glycol | NEG | N/A |
| Water | NEG | N/A |
| Fuel | <5% | <5% |
その他の情報
支払い
追加情報が必要な場合
customercare@ritchiebros.com
配送と受け取り
- アイテムは販売日から8営業日以内に引き取る必要があります。期限を過ぎると、購入者に保管料が発生します。
- お支払いが(税金・管理手数料を含む)全額完了するまで、購入されたアイテムをオークション会場から搬出することはできません。
- ドライバーは、アイテムを受け取る際に、Ritchie Bros. Auctioneersリリースチケットのコピーを携行する必要があります。
- お客様が最低価格で最良の運送業者を簡単に手配できるよう、弊社は信頼のおける配送業者と提携しています。無料見積もりを依頼するか、業者のWebサイトから即時の配送見積もりをお取りください。
見積もりを取る
Ritchie Bros.の充実したドアツードア物流および配送ソリューションで、機器を必要な場所にお届けします。国境、大陸、海を越えてお客様の機器を迅速かつ効率的にお届けするオールインクルーシブサービスで、輸送のすべての工程に対応いたします
一般事項
機械の詳細情報は範囲に制限があり、Ritchie Bros. Auctioneersは、ここに明記するもの以外の設備やコンポーメントの検査は行っていません。特に明記されていない限り、明示的または黙示的かにかかわらず、Ritchie Bros.は機械やそのコンポーネントに関する一切の責任を負わないものとします。機能性、快適性、あるいは関係官庁や規制機関が定める安全基準や要件に関する準拠性、特定目的への適合性、または商品性に関する表明や保証も含まれますが、これらに限るわけではありません。お客様には入札される前に必ず機械の検品を行うことをお勧めします。
機能
機械は負荷の下でのテスト、または利用可能なすべてのギアを使用してのテストを行ったわけではありません。機械が、メーカーの仕様に従って動作されていたか保証はできません。ここで公開されている以外の機能性テストは実施されていません。個々のアンダーキャリッジコンポーネントについては選択中の写真のみが提供されています。このため、アンダーキャリッジ全体の状態を示さないことがあります。
寸法
寸法は、あくまで参考として表示されています。実際に積載された状態での寸法は、トラックやトレーラーの高さ、積載された機械の構成や位置により異なります。オークションの会場から搬出する前に、すべての積載物が運搬可能な状態になっているかの確認は、バイヤーの責任になります。全寸法は、お客様によって採寸・確認を行うようお願いします。運搬に際して、これらの寸法はあくまで参考としてお使いください。