85枚の写真
所在地
Bowling green, KY
Bowling green, KY
シリアル番号
ZF1P101D1C9001077
ZF1P101D1C9001077
Loading...
このロットは、IronClad保険によって保護されています
このロットは有資格検査員による十分かつ詳細な検査を受けています。安心してご購入ください。
ID番号
#14707354
ヤード内
いいえ
年
2019
製造業
資産の種類
シリアル番号またはVIN
ZF1P101D1C9001077
機能
Enclosed Cab, Air Conditioner, Rear View Camera, 56 ft Max Lift Height, 11000 lb Max Lift Capacity, Tier 4, Requires Diesel Exhaust Fluid, 54 in Forks, Hydraulic Coupler, Frame Leveling, Auxiliary Hydraulic Plumbing
注記
Comes with ironclad assurance. Subject to Kentucky sales tax















Picture, Left Front Corner
Picture, Left Rear Corner
Picture, Right Rear Corner
Picture, Right Front Corner
Serial Number / VIN
ZF1P101D1C9001077
CE Mark
No CE mark found
Hour Meter / Odometer
SEE REPORT 511 Hours; The age and condition of the indicates more hours than shown on the hours meter.-No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed.
Paint
Sheet Metal (fiberglass) Condition
Steps/Ladders
Hand Rails
Glass
The door glass is broken out.
Exterior Lights
Operational



Travel Alarm
Operational
Horn
Inoperable
Seat Belts
Operational
Safety Lock Out/Stop
Operational
Current Safety Manual
Current Operator/Maintenance Manual












Mirrors
Seats/Armrests
Hydraulic Controls
No response when unlocked and activated, shows error code and sounds alarm
Steering Control
Drivetrain Controls
Transmission Disconnect Control
Load Charts
Chart book in cab
Engine Oil Pressure
The fault indicator shuts off after the engine oil pressure rises.
Warning Lights
Operational
Gauges
Operational
Air Conditioner
The ambient temperature is too cold to check
Heater
Operational
Limited Function Check
The main components are in place and operational as noted. The rear-view camera is not operational. The hydraulic error light stays on.














Engine
US EPA Label not legible Requires Diesel Exhaust Fluid
Emission Label
Illegible
A/C Compressor
In place; ambient temperature too cold to check operation
Blow-by (subjective visual observation)
Minor
Starter
Operational
Exhaust System
Radiator
Oil Leaks
No dripping leaks
Fuel Leaks
No dripping leaks
Cooling System Leaks
No dripping leaks
Engine - Left Side
Engine - Right Side
DEF / AdBlue Tank
Limited Function Check
After jump starting, the engine ran. The engine would not re-start after shutting down without jump starting.









Transmission
Operational
Transfer Case / Drop Box
Operational
Front Drive Axle
Front Axle Oscillating Pin
Rear Drive Axle
Rear Axle Oscillating Pin
Final Drives
Limited Function Check
The drivetrain was operational.











Pumps (Hydraulics)
Valves
Hydraulic Tank
Hoses (Hydraulics)
Auxiliary Hydraulic Plumbing
Not operationally checked, Front
Boom Lift Cylinder(s)
Telescopic Boom Cylinders
Carriage Tilt Cylinder
Frame Leveling Cylinders
Steering Cylinders
Limited Function Check
The hydraulic system is operational except all boom, auxiliary hydraulic and frame leveling functions are inoperable.

















Boom Condition
Left Side of Boom
Right Side of Boom
Chain / Tensioners
Rollers and Guides
Boom Wear Guides
Steering Linkage
Frame Condition
Limited Function Check
The main chassis components functioned during a limited check.
Master Cylinder
Brake Control
Brake Lines/Hoses
Park Brake
Stopped from a slow roll
Limited Function Check - Brakes
The service brakes are operational, The park brake is operational.
Tire Brands
Mitas
Left Front Tire
Left Rear Tire
Right Rear Tire
Right Front Tire
Wheel Condition
Wheel Studs, Nuts, Lugs




Loader Quick Coupler
Not operationally checked
Load Back Rest
Forks
Oil Sample Analysis
| engine | |
|---|---|
| date of analysis | Nov 12, 2025 |
| Silicon | 15.1 PPM |
| Tin | 2.53 PPM |
| Silver | 0 PPM |
| Aluminum | 1.62 PPM |
| Chromium | 0.32 PPM |
| Lead | 0.95 PPM |
| Copper | 13.77 PPM |
| Nickel | 0.4 PPM |
| Iron | 12.39 PPM |
| Glycol | NEG |
| Water | NEG |
| Fuel | <5% |
機械の詳細情報は範囲に制限があり、Ritchie Bros. Auctioneersは、ここに明記するもの以外の設備やコンポーメントの検査は行っていません。特に明記されていない限り、明示的または黙示的かにかかわらず、Ritchie Bros.は機械やそのコンポーネントに関する一切の責任を負わないものとします。機能性、快適性、あるいは関係官庁や規制機関が定める安全基準や要件に関する準拠性、特定目的への適合性、または商品性に関する表明や保証も含まれますが、これらに限るわけではありません。お客様には入札される前に必ず機械の検品を行うことをお勧めします。
機械は負荷の下でのテスト、または利用可能なすべてのギアを使用してのテストを行ったわけではありません。機械が、メーカーの仕様に従って動作されていたか保証はできません。ここで公開されている以外の機能性テストは実施されていません。個々のアンダーキャリッジコンポーネントについては選択中の写真のみが提供されています。このため、アンダーキャリッジ全体の状態を示さないことがあります。
寸法は、あくまで参考として表示されています。実際に積載された状態での寸法は、トラックやトレーラーの高さ、積載された機械の構成や位置により異なります。オークションの会場から搬出する前に、すべての積載物が運搬可能な状態になっているかの確認は、バイヤーの責任になります。全寸法は、お客様によって採寸・確認を行うようお願いします。運搬に際して、これらの寸法はあくまで参考としてお使いください。