127 Photos
North las vegas, NV
3,112 時間
WLHZ1476KZC041454
Loading...
このロットは、IronClad保険によって保護されています
このロットは有資格検査員による十分かつ詳細な検査を受けています。安心してご購入ください。
ID番号
#12734464
ヤード内
いいえ
年
2015
製造業
モデル
資産の種類
シリアル番号またはVIN
WLHZ1476KZC041454
機能
Air Conditioner, Control Pattern Changer, Cab Screens, Rear View Camera, 2017 US EPA Label, Requires Diesel Exhaust Fluid, 9 ft 6 in Stick, Auxiliary Hydraulic Plumbing, Stick Check Valve, Boom Check Valves, 29.6 in Triple Grouser Track Shoes, Hydraulic Quick Coupler, 60 in Digging Bucket, Auto Lube
注記
LOCATED-IN-LAS-VEGAS-NV
Picture, Left Front Corner
Picture, Left Rear Corner
Picture, Right Rear Corner
Picture, Right Front Corner
Serial Number / VIN
WLHZ1476KZC041454
Hour Meter / Odometer
3112 hrs-No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed.
Paint
Sheet Metal (fiberglass) Condition
Steps/Ladders
Hand Rails
Exterior Lights
Operational
Glass
Travel Alarm
Operational
Horn
Operational
Seat Belts
Operational
Safety Lock Out/Stop
Operational
Swing Brake
Operational
Current Safety Manual
Current Operator/Maintenance Manual
Seats/Armrests
Mirrors
Steering Controls
Hydraulic Controls
Auxiliary Hydraulic Control
Drivetrain Controls
Dash Console
Engine Oil Pressure
The fault indicator shuts off after the engine oil pressure rises.
Warning Lights
Operational
Gauges
Operational
Air Conditioner
Operational
Heater
Operational
Limited Function Check
The main components are in place and operational as noted.
Engine
2017 US EPA Label, Requires Diesel Exhaust Fluid
Emission Label
A/C Compressor
Operational
Blow-by (subjective visual observation)
Minor
Starter
Operational
Exhaust System
Radiator
Oil Leaks
No dripping leaks
Fuel Leaks
No dripping leaks
Cooling System Leaks
No dripping leaks
Engine - Left Side
Engine - Right Side
DEF / AdBlue Tank
Limited Function Check
The engine started and ran.
Left Drive Motor
Right Drive Motor
Left Final Drive
Right Final Drive
Limited Function Check
The drivetrain was operational.
Pumps (Hydraulics)
Valves
Hydraulic Tank
Hydraulic Control Pattern Changer
Hoses (Hydraulics)
Seepage
Auxiliary Hydraulic Plumbing
Not operationally checked, End of stick, Seepage
Swing Motor
Hydraulic Center Swivel
Boom Lift Cylinder(s)
Seepage
Stick Cylinder
Dripping leak
Bucket Cylinder
Seepage
Limited Function Check
The hydraulic system was operational.
Boom Condition
Dented on the bottom
Stick Condition
Boom Base Pin and Bushings
Pin and Bushings Boom to Stick
Pins and Bushings Stick to Coupler
Turntable Bearing
Bottom Covers
Limited Function Check
The main components were operational with damage as noted.
Left Roller Frame
Left Track Tensioner
Not tested
Left Track Shoes
Left Grouser Height
37 mm
Left Track Links
Left Carrier Rollers
Left Track Rollers
Left Idler
Left Sprocket
Right Roller Frame
Right Track Tensioner
Not tested
Right Track Shoes
Right Grouser Height
37 mm
Right Track Links
Right Carrier Rollers
Right Track Rollers
Right Idler
Right Sprocket
Excavator Bucket Condition
Cutting Edge / Teeth / Adapters
Quick Coupler
Operational
Oil Sample Analysis
engine | hydraulic | |
---|---|---|
date of analysis | Dec 06, 2024 | Dec 06, 2024 |
Silicon | 3.37 PPM | 1.63 PPM |
Tin | 0.17 PPM | 1.18 PPM |
Silver | 0 PPM | 0 PPM |
Aluminum | 0.47 PPM | 1.37 PPM |
Chromium | 0 PPM | 0.3 PPM |
Lead | 0.03 PPM | 0.98 PPM |
Copper | 0.07 PPM | 10.54 PPM |
Nickel | 0.56 PPM | 0.74 PPM |
Iron | 1.6 PPM | 7.03 PPM |
Glycol | NEG | N/A |
Water | NEG | N/A |
Fuel | <5% | <5% |
機械の詳細情報は範囲に制限があり、Ritchie Bros. Auctioneersは、ここに明記するもの以外の設備やコンポーメントの検査は行っていません。特に明記されていない限り、明示的または黙示的かにかかわらず、Ritchie Bros.は機械やそのコンポーネントに関する一切の責任を負わないものとします。機能性、快適性、あるいは関係官庁や規制機関が定める安全基準や要件に関する準拠性、特定目的への適合性、または商品性に関する表明や保証も含まれますが、これらに限るわけではありません。お客様には入札される前に必ず機械の検品を行うことをお勧めします。
機械は負荷の下でのテスト、または利用可能なすべてのギアを使用してのテストを行ったわけではありません。機械が、メーカーの仕様に従って動作されていたか保証はできません。ここで公開されている以外の機能性テストは実施されていません。個々のアンダーキャリッジコンポーネントについては選択中の写真のみが提供されています。このため、アンダーキャリッジ全体の状態を示さないことがあります。
寸法は、あくまで参考として表示されています。実際に積載された状態での寸法は、トラックやトレーラーの高さ、積載された機械の構成や位置により異なります。オークションの会場から搬出する前に、すべての積載物が運搬可能な状態になっているかの確認は、バイヤーの責任になります。全寸法は、お客様によって採寸・確認を行うようお願いします。運搬に際して、これらの寸法はあくまで参考としてお使いください。