76枚の写真
所在地
Lenoir City, TN
Lenoir City, TN
使用状況
9,148 時間
9,148 時間
シリアル番号
CAT0773FAEED00838
CAT0773FAEED00838
Loading...
このロットは、IronClad保険によって保護されています
このロットは有資格検査員による十分かつ詳細な検査を受けています。安心してご購入ください。
ID番号
#14778294
ヤード内
いいえ
機能
Air Conditioner, 2008 US EPA Label, Heated Body, 24.00R35 Tires, Equipment-from-Twin-K-Construction
注記
COMES WITH IRONCLAD ASSURANCE. SUBJECT TO TENNESSEE SALES TAX.















Serial Number / VIN
CAT0773FAEED00838
Hour Meter / Odometer
9148 hrs-No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed.
Paint
Sheet Metal (fiberglass) Condition
Steps/Ladders
Hand Rails
Exterior Lights
Some not operational, Front lights lights are not operational
Travel Alarm
Inoperable
Horn
Inoperable
Seat Belts
Operational














Seats/Armrests
Mirrors
Steering Controls
Hydraulic Controls
Drivetrain Controls
Dash Console
Engine Oil Pressure
No oil pressure indicator
Warning Lights
Operational, Gear warning light on light stays on
Gauges
Operational
Air Conditioner
The ambient temperature is too cold to check
Heater
Operational
Limited Function Check
The main components are in place and operational as noted.













Engine
2008 US EPA Label
Emission Label
A/C Compressor
In place; ambient temperature too cold to check operation
Blow-by (subjective visual observation)
Visible
Starter
Operational
Exhaust System
Radiator
Oil Leaks
No dripping leaks Collection rear of engine
Fuel Leaks
No dripping leaks
Cooling System Leaks
No dripping leaks
Engine - Left Side
Engine - Right Side
Limited Function Check
After jump starting, the engine ran.






Transmission
Operational
Rear Drive Axle
Possible wheel seal leak left side
Final Drives
Limited Function Check
The drivetrain was operational.










Pumps (Hydraulics)
Seepage
Valves
Hydraulic Tank
Low fluid
Hoses
Dripping leak
Cylinders
Steering Cylinders
Dripping leak on the left cylinder
Limited Function Check
The hydraulic system was operational.


















Steering Linkage
Frame Condition
Suspension Cylinders
Suspension Pivot Points
Heavy wear
Limited Function Check
The main chassis components functioned during a limited check.
Master Cylinder/Brake Control
Brake Lines/Hoses
Front brake lines have been disconnected
Park Brake
Limited Function Check - Brakes
The brake system functioned, stopping and holding the machine.
Left Front Steer Tire
Continental
Right Front Steer Tire
Continental
Wheel Condition
Wheel Studs, Nuts, Lugs
Bed Body
Bed Liner
Bed Pads
Left front pad missing
Hinge Points
Limited Function Check
The main chassis components were operational in a limited check.
Oil Sample Analysis
| engine | hydraulic | |
|---|---|---|
| date of analysis | Mar 17, 2026 | Mar 17, 2026 |
| Silicon | 2.87 PPM | 21.29 PPM |
| Tin | 0 PPM | 0 PPM |
| Silver | 0.02 PPM | 0.04 PPM |
| Aluminum | 0.54 PPM | 10.51 PPM |
| Chromium | 0.63 PPM | 1.08 PPM |
| Lead | 0.53 PPM | 0.79 PPM |
| Copper | 2.96 PPM | 18.97 PPM |
| Nickel | 0.28 PPM | 2.79 PPM |
| Iron | 22.66 PPM | 23.9 PPM |
| Glycol | NEG | N/A |
| Water | NEG | N/A |
| Fuel | <5% | <5% |
機械の詳細情報は範囲に制限があり、Ritchie Bros. Auctioneersは、ここに明記するもの以外の設備やコンポーメントの検査は行っていません。特に明記されていない限り、明示的または黙示的かにかかわらず、Ritchie Bros.は機械やそのコンポーネントに関する一切の責任を負わないものとします。機能性、快適性、あるいは関係官庁や規制機関が定める安全基準や要件に関する準拠性、特定目的への適合性、または商品性に関する表明や保証も含まれますが、これらに限るわけではありません。お客様には入札される前に必ず機械の検品を行うことをお勧めします。
機械は負荷の下でのテスト、または利用可能なすべてのギアを使用してのテストを行ったわけではありません。機械が、メーカーの仕様に従って動作されていたか保証はできません。ここで公開されている以外の機能性テストは実施されていません。個々のアンダーキャリッジコンポーネントについては選択中の写真のみが提供されています。このため、アンダーキャリッジ全体の状態を示さないことがあります。
寸法は、あくまで参考として表示されています。実際に積載された状態での寸法は、トラックやトレーラーの高さ、積載された機械の構成や位置により異なります。オークションの会場から搬出する前に、すべての積載物が運搬可能な状態になっているかの確認は、バイヤーの責任になります。全寸法は、お客様によって採寸・確認を行うようお願いします。運搬に際して、これらの寸法はあくまで参考としてお使いください。